DO NOT MERGE: Fix a couple of bugs in CEC services

- Correct conversion for byte to int for cec opcode
- Use the right Handler.obtainMessage() to pass an integer variable

Change-Id: Ie3e86225f1702decce454aeb197911a371f51c17
This commit is contained in:
Jinsuk Kim
2014-05-28 17:42:56 +09:00
committed by Jungshik Jang
parent 304b4a7281
commit a8fd44b74b
2 changed files with 3 additions and 2 deletions

View File

@@ -46,7 +46,7 @@ public final class HdmiCecMessage implements Parcelable {
public HdmiCecMessage(int source, int destination, int opcode, byte[] params) {
mSource = source;
mDestination = destination;
mOpcode = opcode;
mOpcode = opcode & 0xFF;
mParams = Arrays.copyOf(params, params.length);
}

View File

@@ -133,7 +133,8 @@ abstract class FeatureAction {
@Override
public void sendTimerMessage(int state, long delayMillis) {
sendMessageDelayed(obtainMessage(MSG_TIMEOUT, state), delayMillis);
// The third argument(0) is not used.
sendMessageDelayed(obtainMessage(MSG_TIMEOUT, state, 0), delayMillis);
}
@Override