2d8a3908d2b0a74ccdecd97e86e7bfda1caa218e
Under certain circumstances, the power manager might continue to hold the display wakelock long after the display had been turned off due to the mDisplayReady flag having an incorrect value. 1. An inverted conditional caused DisplayPowerState to incorrectly signal the screen on ready state. 2. The DisplayPowerController failed to clear the block screen on flag in the case where the screen was turned off before it became unblocked from turning on. This could happen when the display was rapidly turned on-off-on-off. Bug: 13248135 Change-Id: I8faa3034695c83c8cd35613d81acccf40d22128d
am
0a3bc3c4: am 2cc271eb: am d36ede39: Merge "Allow lights-out + bar icon dimming on low-end devices." into klp-dev
cherrypick from ics-mr1 docs: source for nw app Change-Id: If50f407a0e56fa802fe9beedaa650e3a131872b2
…