Update low battery notification mechanism
- Update warning and severe trigger percentage - Update low battery notification trigger condition to fixed value instead of remaining time - Update low battery notification text - Update start saver confirmation notification text - Use severe low battery dialog if available Screenshot: https://screenshot.googleplex.com/iZt43YU6fHQPNpy.png Bug: 207470943 Bug: 209932572 Test: atest SystemUITests Change-Id: I851e635e748a5315f9780a1344c2068cda14d95e
This commit is contained in:
@@ -1207,13 +1207,13 @@
|
||||
|
||||
<!-- Display low battery warning when battery level dips to this value.
|
||||
Also, the battery stats are flushed to disk when we hit this level. -->
|
||||
<integer name="config_criticalBatteryWarningLevel">5</integer>
|
||||
<integer name="config_criticalBatteryWarningLevel">10</integer>
|
||||
|
||||
<!-- Shutdown if the battery temperature exceeds (this value * 0.1) Celsius. -->
|
||||
<integer name="config_shutdownBatteryTemperature">680</integer>
|
||||
|
||||
<!-- Display low battery warning when battery level dips to this value -->
|
||||
<integer name="config_lowBatteryWarningLevel">15</integer>
|
||||
<integer name="config_lowBatteryWarningLevel">20</integer>
|
||||
|
||||
<!-- The default suggested battery % at which we enable battery saver automatically. -->
|
||||
<integer name="config_lowBatteryAutoTriggerDefaultLevel">15</integer>
|
||||
|
||||
@@ -482,6 +482,9 @@
|
||||
space -->
|
||||
<bool name="config_showBatteryEstimateQSBH">false</bool>
|
||||
|
||||
<!-- Whether to show a severe low battery dialog. -->
|
||||
<bool name="config_severe_battery_dialog">false</bool>
|
||||
|
||||
<!-- A path similar to frameworks/base/core/res/res/values/config.xml
|
||||
config_mainBuiltInDisplayCutout that describes a path larger than the exact path of a display
|
||||
cutout. If present as well as config_enableDisplayCutoutProtection is set to true, then
|
||||
|
||||
@@ -21,7 +21,13 @@
|
||||
<string name="app_label">System UI</string>
|
||||
|
||||
<!-- When the battery is low, this is displayed to the user in a dialog. The title of the low battery alert. [CHAR LIMIT=NONE]-->
|
||||
<string name="battery_low_title">Battery may run out soon</string>
|
||||
<string name="battery_low_title">Turn on Battery Saver?</string>
|
||||
|
||||
<!-- When the battery is low, this is displayed to the user in a dialog. The description of the low battery alert. [CHAR LIMIT=NONE]-->
|
||||
<string name="battery_low_description">You have <xliff:g id="percentage" example="20%">%s</xliff:g> battery left. Battery Saver turns on Dark theme, restricts background activity, and delays notifications.</string>
|
||||
|
||||
<!-- When the battery is low at first time, this is displayed to the user in a dialog. The description of the low battery alert. [CHAR LIMIT=NONE]-->
|
||||
<string name="battery_low_intro">Battery Saver turns on Dark theme, restricts background activity, and delays notifications.</string>
|
||||
|
||||
<!-- A message that appears when the battery level is getting low in a dialog. This is
|
||||
appended to the subtitle of the low battery alert. "percentage" is the percentage of battery
|
||||
|
||||
@@ -118,6 +118,8 @@ public class PowerNotificationWarnings implements PowerUI.WarningsUI {
|
||||
private static final String ACTION_AUTO_SAVER_NO_THANKS =
|
||||
"PNW.autoSaverNoThanks";
|
||||
|
||||
private static final String ACTION_ENABLE_SEVERE_BATTERY_DIALOG = "PNW.enableSevereDialog";
|
||||
|
||||
private static final String SETTINGS_ACTION_OPEN_BATTERY_SAVER_SETTING =
|
||||
"android.settings.BATTERY_SAVER_SETTINGS";
|
||||
public static final String BATTERY_SAVER_SCHEDULE_SCREEN_INTENT_ACTION =
|
||||
@@ -253,20 +255,25 @@ public class PowerNotificationWarnings implements PowerUI.WarningsUI {
|
||||
}
|
||||
|
||||
protected void showWarningNotification() {
|
||||
final String percentage = NumberFormat.getPercentInstance()
|
||||
.format((double) mCurrentBatterySnapshot.getBatteryLevel() / 100.0);
|
||||
|
||||
// get shared standard notification copy
|
||||
String title = mContext.getString(R.string.battery_low_title);
|
||||
String contentText;
|
||||
|
||||
// get correct content text if notification is hybrid or not
|
||||
if (mCurrentBatterySnapshot.isHybrid()) {
|
||||
contentText = getHybridContentString(percentage);
|
||||
} else {
|
||||
contentText = mContext.getString(R.string.battery_low_percent_format, percentage);
|
||||
if (showSevereLowBatteryDialog()) {
|
||||
mContext.sendBroadcast(new Intent(ACTION_ENABLE_SEVERE_BATTERY_DIALOG)
|
||||
.setPackage(mContext.getPackageName())
|
||||
.addFlags(Intent.FLAG_RECEIVER_REGISTERED_ONLY
|
||||
| Intent.FLAG_RECEIVER_FOREGROUND));
|
||||
// Reset the state once dialog been enabled
|
||||
dismissLowBatteryNotification();
|
||||
mPlaySound = false;
|
||||
return;
|
||||
}
|
||||
|
||||
final int warningLevel = mContext.getResources().getInteger(
|
||||
com.android.internal.R.integer.config_lowBatteryWarningLevel);
|
||||
final String percentage = NumberFormat.getPercentInstance()
|
||||
.format((double) warningLevel / 100.0);
|
||||
final String title = mContext.getString(R.string.battery_low_title);
|
||||
final String contentText = mContext.getString(
|
||||
R.string.battery_low_description, percentage);
|
||||
|
||||
final Notification.Builder nb =
|
||||
new Notification.Builder(mContext, NotificationChannels.BATTERY)
|
||||
.setSmallIcon(R.drawable.ic_power_low)
|
||||
@@ -284,7 +291,7 @@ public class PowerNotificationWarnings implements PowerUI.WarningsUI {
|
||||
}
|
||||
// Make the notification red if the percentage goes below a certain amount or the time
|
||||
// remaining estimate is disabled
|
||||
if (!mCurrentBatterySnapshot.isHybrid() || mBucket < 0
|
||||
if (!mCurrentBatterySnapshot.isHybrid() || mBucket < -1
|
||||
|| mCurrentBatterySnapshot.getTimeRemainingMillis()
|
||||
< mCurrentBatterySnapshot.getSevereThresholdMillis()) {
|
||||
nb.setColor(Utils.getColorAttrDefaultColor(mContext, android.R.attr.colorError));
|
||||
@@ -303,6 +310,13 @@ public class PowerNotificationWarnings implements PowerUI.WarningsUI {
|
||||
mNoMan.notifyAsUser(TAG_BATTERY, SystemMessage.NOTE_POWER_LOW, n, UserHandle.ALL);
|
||||
}
|
||||
|
||||
private boolean showSevereLowBatteryDialog() {
|
||||
final boolean isSevereState = !mCurrentBatterySnapshot.isHybrid() || mBucket < -1;
|
||||
final boolean useSevereDialog = mContext.getResources().getBoolean(
|
||||
R.bool.config_severe_battery_dialog);
|
||||
return isSevereState && useSevereDialog;
|
||||
}
|
||||
|
||||
private void showAutoSaverSuggestionNotification() {
|
||||
final CharSequence message = mContext.getString(R.string.auto_saver_text);
|
||||
final Notification.Builder nb =
|
||||
@@ -662,8 +676,7 @@ public class PowerNotificationWarnings implements PowerUI.WarningsUI {
|
||||
|
||||
// If there's no link, use the string with no "learn more".
|
||||
if (TextUtils.isEmpty(learnMoreUrl)) {
|
||||
return mContext.getText(
|
||||
com.android.internal.R.string.battery_saver_description);
|
||||
return mContext.getText(R.string.battery_low_intro);
|
||||
}
|
||||
|
||||
// If we have a link, use the string with the "learn more" link.
|
||||
|
||||
@@ -69,7 +69,7 @@ public class PowerUI extends CoreStartable implements CommandQueue.Callbacks {
|
||||
private static final long TEMPERATURE_LOGGING_INTERVAL = DateUtils.HOUR_IN_MILLIS;
|
||||
private static final int MAX_RECENT_TEMPS = 125; // TEMPERATURE_LOGGING_INTERVAL plus a buffer
|
||||
static final long THREE_HOURS_IN_MILLIS = DateUtils.HOUR_IN_MILLIS * 3;
|
||||
private static final int CHARGE_CYCLE_PERCENT_RESET = 45;
|
||||
private static final int CHARGE_CYCLE_PERCENT_RESET = 30;
|
||||
private static final long SIX_HOURS_MILLIS = Duration.ofHours(6).toMillis();
|
||||
public static final int NO_ESTIMATE_AVAILABLE = -1;
|
||||
private static final String BOOT_COUNT_KEY = "boot_count";
|
||||
@@ -206,7 +206,8 @@ public class PowerUI extends CoreStartable implements CommandQueue.Callbacks {
|
||||
*
|
||||
* 1 means that the battery is "ok"
|
||||
* 0 means that the battery is between "ok" and what we should warn about.
|
||||
* less than 0 means that the battery is low
|
||||
* less than 0 means that the battery is low, -1 means the battery is reaching warning level,
|
||||
* -2 means the battery is reaching severe level.
|
||||
*/
|
||||
private int findBatteryLevelBucket(int level) {
|
||||
if (level >= mLowBatteryAlertCloseLevel) {
|
||||
@@ -388,12 +389,8 @@ public class PowerUI extends CoreStartable implements CommandQueue.Callbacks {
|
||||
@VisibleForTesting
|
||||
void maybeShowHybridWarning(BatteryStateSnapshot currentSnapshot,
|
||||
BatteryStateSnapshot lastSnapshot) {
|
||||
// if we are now over 45% battery & 6 hours remaining so we can trigger hybrid
|
||||
// notification again
|
||||
final long timeRemainingMillis = currentSnapshot.getTimeRemainingMillis();
|
||||
if (currentSnapshot.getBatteryLevel() >= CHARGE_CYCLE_PERCENT_RESET
|
||||
&& (timeRemainingMillis > SIX_HOURS_MILLIS
|
||||
|| timeRemainingMillis == NO_ESTIMATE_AVAILABLE)) {
|
||||
// if we are now over 30% battery, we can trigger hybrid notification again
|
||||
if (currentSnapshot.getBatteryLevel() >= CHARGE_CYCLE_PERCENT_RESET) {
|
||||
mLowWarningShownThisChargeCycle = false;
|
||||
mSevereWarningShownThisChargeCycle = false;
|
||||
if (DEBUG) {
|
||||
@@ -403,6 +400,7 @@ public class PowerUI extends CoreStartable implements CommandQueue.Callbacks {
|
||||
|
||||
final boolean playSound = currentSnapshot.getBucket() != lastSnapshot.getBucket()
|
||||
|| lastSnapshot.getPlugged();
|
||||
final long timeRemainingMillis = currentSnapshot.getTimeRemainingMillis();
|
||||
|
||||
if (shouldShowHybridWarning(currentSnapshot)) {
|
||||
mWarnings.showLowBatteryWarning(playSound);
|
||||
@@ -444,19 +442,13 @@ public class PowerUI extends CoreStartable implements CommandQueue.Callbacks {
|
||||
return false;
|
||||
}
|
||||
|
||||
final long timeRemainingMillis = snapshot.getTimeRemainingMillis();
|
||||
// Only show the low warning if enabled once per charge cycle & no battery saver
|
||||
final boolean canShowWarning = snapshot.isLowWarningEnabled()
|
||||
&& !mLowWarningShownThisChargeCycle && !snapshot.isPowerSaver()
|
||||
&& ((timeRemainingMillis != NO_ESTIMATE_AVAILABLE
|
||||
&& timeRemainingMillis < snapshot.getLowThresholdMillis())
|
||||
|| snapshot.getBatteryLevel() <= snapshot.getLowLevelThreshold());
|
||||
final boolean canShowWarning = !mLowWarningShownThisChargeCycle && !snapshot.isPowerSaver()
|
||||
&& snapshot.getBatteryLevel() <= snapshot.getLowLevelThreshold();
|
||||
|
||||
// Only show the severe warning once per charge cycle
|
||||
final boolean canShowSevereWarning = !mSevereWarningShownThisChargeCycle
|
||||
&& ((timeRemainingMillis != NO_ESTIMATE_AVAILABLE
|
||||
&& timeRemainingMillis < snapshot.getSevereThresholdMillis())
|
||||
|| snapshot.getBatteryLevel() <= snapshot.getSevereLevelThreshold());
|
||||
&& snapshot.getBatteryLevel() <= snapshot.getSevereLevelThreshold();
|
||||
|
||||
final boolean canShow = canShowWarning || canShowSevereWarning;
|
||||
|
||||
|
||||
@@ -430,12 +430,6 @@ public class PowerUITest extends SysuiTestCase {
|
||||
state.mIsPowerSaver = true;
|
||||
shouldShow = mPowerUI.shouldShowHybridWarning(state.get());
|
||||
assertThat(shouldShow).isFalse();
|
||||
|
||||
state.mIsPowerSaver = false;
|
||||
// if disabled we should not show the low warning.
|
||||
state.mIsLowLevelWarningEnabled = false;
|
||||
shouldShow = mPowerUI.shouldShowHybridWarning(state.get());
|
||||
assertThat(shouldShow).isFalse();
|
||||
}
|
||||
|
||||
@Test
|
||||
|
||||
Reference in New Issue