Set default Wear rotary fling thresholds
Setting the configs to enable RSB fling. We are using the same thresholds as we use for touch, which were the thresholds used for Wear 3/4. We can later change these thresholds if needed. Bug: 294275117 Test: manual Change-Id: I95a0a6223e340acffce5c28efb08bdfaecd7bdf9
This commit is contained in:
@@ -33,6 +33,14 @@
|
||||
<!-- Maximum velocity to initiate a fling, as measured in dips per second. -->
|
||||
<dimen name="config_viewMaxFlingVelocity">8000dp</dimen>
|
||||
|
||||
<!-- Minimum velocity (absolute value) to initiate a fling from a rotary encoder device, as
|
||||
measured in dips per second. Setting this to -1dp disables rotary encoder fling. -->
|
||||
<dimen name="config_viewMinRotaryEncoderFlingVelocity">500dp</dimen>
|
||||
|
||||
<!-- Maximum velocity (absolute value) to initiate a fling from a rotary encoder device, as
|
||||
measured in dips per second. Setting this to -1dp disables rotary encoder fling. -->
|
||||
<dimen name="config_viewMaxRotaryEncoderFlingVelocity">8000dp</dimen>
|
||||
|
||||
<!-- Number of notifications to keep in the notification service historical archive.
|
||||
Reduced intentionally for watches to retain minimal memory footprint -->
|
||||
<integer name="config_notificationServiceArchiveSize">1</integer>
|
||||
|
||||
Reference in New Issue
Block a user