Merge "Add new hardware reliability actions and fields" into pi-dev
This commit is contained in:
@@ -205,6 +205,14 @@ message MetricsEvent {
|
||||
HARDWARE_FAILURE_FINGERPRINT_TOO_MANY_DEAD_PIXELS = 5;
|
||||
}
|
||||
|
||||
enum IoOperation {
|
||||
IOOP_UNKNOWN = 0;
|
||||
IOOP_READ = 1;
|
||||
IOOP_WRITE = 2;
|
||||
IOOP_UNMAP = 3;
|
||||
IOOP_SYNC = 4;
|
||||
}
|
||||
|
||||
// Known visual elements: views or controls.
|
||||
enum View {
|
||||
// Unknown view
|
||||
@@ -5931,8 +5939,7 @@ message MetricsEvent {
|
||||
// ACTION: Battery health snapshot
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
// uses FIELD_END_BATTERY_PERCENT for batt %
|
||||
// uses FIELD_END_BATTERY_UA for instantaneous current load
|
||||
// uses FIELD_END_BATTERY_PERCENT for instantaneous batt %
|
||||
ACTION_BATTERY_HEALTH = 1433;
|
||||
|
||||
// FIELD: Battery health snapshot type - min daily voltage, resistance, etc.
|
||||
@@ -5940,31 +5947,33 @@ message MetricsEvent {
|
||||
// OS: P
|
||||
FIELD_BATTERY_HEALTH_SNAPSHOT_TYPE = 1434;
|
||||
|
||||
// FIELD: Battery temperature at snapshop.
|
||||
// FIELD: Battery temperature at snapshot, in 1/10 deg C.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_BATTERY_TEMPERATURE = 1435;
|
||||
FIELD_BATTERY_TEMPERATURE_DECI_C = 1435;
|
||||
|
||||
// FIELD: Battery voltage at snapshot.
|
||||
// FIELD: Battery voltage at snapshot, in microVolts.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_BATTERY_VOLTAGE = 1436;
|
||||
FIELD_BATTERY_VOLTAGE_UV = 1436;
|
||||
|
||||
// FIELD: Battery open circuit voltage at snapshot.
|
||||
// FIELD: Battery open circuit voltage at snapshot, in microVolts.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_BATTERY_OPEN_CIRCUIT_VOLTAGE = 1437;
|
||||
FIELD_BATTERY_OPEN_CIRCUIT_VOLTAGE_UV = 1437;
|
||||
|
||||
// ACTION: Battery charge cycles
|
||||
// Number of times the battery has charged beyond a
|
||||
// ACTION: Number of times the battery has charged beyond a
|
||||
// fractional threshold of full capacity.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
ACTION_BATTERY_CHARGE_CYCLES = 1438;
|
||||
|
||||
// FIELD: Battery charge cycles
|
||||
// Number of times the battery has charged beyond a
|
||||
// fractional threshold of full capacity.
|
||||
// FIELD: BATTERY_CHARGE_CYCLES - Number of times the battery has charged
|
||||
// beyond a fractional threshold of full
|
||||
// capacity. A comma-separated string of
|
||||
// buckets. If there are eight buckets,
|
||||
// each bucket represents charging to n/8
|
||||
// percent full.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_BATTERY_CHARGE_CYCLES = 1439;
|
||||
@@ -5980,6 +5989,62 @@ message MetricsEvent {
|
||||
// OS: P
|
||||
DIALOG_BLUETOOTH_DISABLE_A2DP_HW_OFFLOAD = 1441;
|
||||
|
||||
// ACTION: SLOW_IO - I/O operation took longer than threshold,
|
||||
// reported aggregated per day when > 0.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
ACTION_SLOW_IO = 1442;
|
||||
|
||||
// FIELD: IO_OPERATION_TYPE - The IO Operation that caused the high latency.
|
||||
// The value is an integer from the enum IoOperation.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_IO_OPERATION_TYPE = 1443;
|
||||
|
||||
// FIELD: IO_OPERATION_COUNT - Count of how many times this slow IO operation happened
|
||||
// over the past 24hr (reported only if > 0).
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_IO_OPERATION_COUNT = 1444;
|
||||
|
||||
// ACTION: Speaker Imedance - last recorded speaker impedance.
|
||||
// reported max once per 24hr.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
ACTION_SPEAKER_IMPEDANCE = 1445;
|
||||
|
||||
// FIELD: Speaker Impedance in milliohms.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_SPEAKER_IMPEDANCE_MILLIOHMS = 1446;
|
||||
|
||||
// FIELD: Speaker Location - identifies one of several speakers on a device.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_SPEAKER_LOCATION = 1447;
|
||||
|
||||
// FIELD: Instantaneous battery resistance in microohms.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_BATTERY_RESISTANCE_UOHMS = 1448;
|
||||
|
||||
// FIELD: Instantaneous battery current - in microamps.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_BATTERY_CURRENT_UA = 1449;
|
||||
|
||||
// FIELD: HARDWARE_LOCATION - Identifier for instance of a hardware type on a
|
||||
// board.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
FIELD_HARDWARE_LOCATION = 1450;
|
||||
|
||||
// ACTION: BATTERY_CAUSED_SHUTDOWN - shutdown due to low battery, the
|
||||
// action is logged after the subsequent boot.
|
||||
// CATEGORY: OTHER
|
||||
// OS: P
|
||||
ACTION_BATTERY_CAUSED_SHUTDOWN = 1451;
|
||||
|
||||
// ---- End P Constants, all P constants go above this line ----
|
||||
// Add new aosp constants above this line.
|
||||
// END OF AOSP CONSTANTS
|
||||
|
||||
Reference in New Issue